Favorite
Release Notes Intelli-Site 4.0.28.10
Author: Lori Tassin Reference Number: AA-00552 Views: 18119 Created: 09-20-2017 04:43 PM Last Updated: 03-07-2018 02:41 PM 0 Rating/ Voters

View products to which this article applies.

Overview

This article contains the release notes for Intelli-Site v4.28.10.  The following sections describe the release in detail and provide late-breaking or other information that supplements the main documentation.

This is a maintenance release that improves quality, reliability, and performance.  All users are encouraged to upgrade to this release.

New Features

The following software features were added:

  • For an unlicensed version (a.k.a. the demo license), the reader count has been increased to 50.
The following Panels were added or upgraded:

  • N/A

Resolved Issues

The following issues affecting all products have been resolved:

  • Configuration Utility
    • The project password can be changed for the current project using the Create or setup project button.
    • Intelli-Site 4.0.27.10 would not allow the creation of additional projects. This has been fixed. This only affects integrators who manage multiple installations. End-Users were not affected as they only run one project.
  • Desktop Client
    • Access Management View
      • Deleting a card now properly sends a delete card message to the panels.
      • Deleting a personnel record now properly sends a delete card message to the panels.
      • The [Search] button is now disabled when a query is active.
      • The [Clear Query] button is now disabled when a record is being edited or added.
      • With a large number of cards on a busy system, there was a chance that the data fields would be pre-populated with the selected personnel and token when a query is cleared and another one immediately initiated. To prevent this, all buttons are disabled until the tables are fully populated.
    • Design View
      • Selecting a screen object in the Tree no longer overrides the Freeze Edit checkbox.
      • Report Parameter Settings nodes now contain the proper parameter settings for the type of report. These settings nodes can be saved for use in Reports View. They are child nodes of the specific report nodes in the Project Node Tree. Double-clicking on these nodes in Reports View will generate the report using these settings.
      • The Delete option is no longer possible for child nodes of panels that should not be deleted individually.
    • Information Manager
      • No messages will be sent to the Debug tab until the Debug tab is visible. This is a tech support option much like the Log Messages checkboxes in the Configuration Utility. You should only display the Debug tab at the request of tech support.
      • The index error has been fixed when there are a lot of alarms in the Alarm Queue that are acknowledged and cleared.
    • Scheduled Events View
      • When an active scheduled event is deleted, the points that were set on by the event will be cleared as long as there are no other active events that have set them.
      • When an active scheduled event is deleted, the event point is cleared.
  • Drivers
    • Access Control Panel Types
      • When the [Cards] download button is clicked on the Quick Config dialog or the properties dialog, or when the [Download Assigned Cards] button in Access Management View is clicked, only cards with access sets that include the panel are downloaded to it.
    • Accutech
      • The Driver Service no longer crashes when it receives a message from a Zone that has not been configured in Intelli-Site. In addition, those zones are reported to the driver Messages window if it is open.
    • Compass
      • The download flags now clear after auto-detect.
      • Only one Compass communication method is allowed per Compass driver.
  • Engine Service
    • When a valid read occurs for a card that has been deleted, the Engine will automatically send a delete card message. This condition can only happen if the delete card message did not make it to the panel when the card was deleted. This is the corollary to the automatic download of valid cards.
The following issues specific to Intelli-Site Lite have been resolved:

  • N/A
Below are issues related to specific OEM versions:

  • N/A

Known Limitations

N/A

Products

Applies to:
  • Intelli-Site
  • Intelli-Site Lite
  • MASC
  • MASC Lite

Go to Top

Copyright © 2016-2017 OSSI, LLC.  All rights 

reserved.

Intelli-Site® 

is registered in U.S. Patent & 

Trademark Office. 

 

All other registered and unregistered

 

trademarks are the sole property of their 

respective owners.